The attenuation is established twice: by resistance at DC and by capacitance as frequency increases. The front end, cable, BNC section and oscilloscope input therefore work together as one system. That is also why a passive probe must be compensated to the oscilloscope to which it is connected.
The front end contains the probe tip, the resistive divider and the parallel capacitive divider. A small series resistance may also be present for frequency-response optimization; it is not part of the 10:1 divider calculation. In low-voltage designs, the 9 MΩ path may be implemented with a single resistor. Higher-voltage designs commonly distribute the resistive and capacitive networks across several components to meet creepage, clearance and single-fault design requirements. The circuitry is typically arranged inside a grounded mechanical tube. Compact geometry improves access to small components while spacing controls stray capacitance.
A passive probe cable behaves as a transmission line with distributed resistance, inductance and capacitance. Above approximately 100 MHz, probes intended for a flat response commonly use lossy transmission-line techniques to damp reflections and control the response.
The PCB between the cable and BNC connector contains the compensation network and may also provide probe readout identification through an additional contact and resistor. High-bandwidth passive probes may use several adjustment elements in this section. Designs without additional trimmers rely on tighter component tolerances and fixed compensation networks.
The return path is equally important. Ground-lead inductance increases with lead length and can produce peaking and ringing at higher frequencies. A typical wire ground lead contributes roughly 1 nH per millimeter. A 100 mm lead can therefore add around 100 nH to the measurement loop. Short ground springs and other low-inductance connections reduce this effect for fast transitions and high-frequency signals.
A 10:1 passive probe works by making the resistive and capacitive divider ratios agree. The front end establishes both paths, the cable becomes part of the AC network, the BNC-end compensation matches the probe to the oscilloscope input, and the ground connection completes the measurement loop.
At DC, only the resistors set the division ratio. In the simplified example below, the probe front end contributes 9 MΩ and the oscilloscope input contributes 1 MΩ.


Fig. 1. Simplified DC signal path in a 10:1 passive oscilloscope probe. At DC, the attenuation is set by the 9 MΩ probe resistance and the 1 MΩ oscilloscope input.
As frequency increases, the capacitive path becomes important. For the probe to remain a 10:1 attenuator, the capacitive divider must produce the same ratio as the resistive divider.


Fig. 2. Simplified AC signal path. The capacitive divider is matched to the 10:1 resistive divider so that attenuation remains consistent as frequency increases.
Oscilloscope input capacitance varies between instruments. The compensation trimmer changes the capacitance at the BNC end so the probe can be matched to the oscilloscope input.
A square wave is useful because it contains both low- and high-frequency components, making errors in the probe’s frequency response visible directly in the waveform.

Fig. 3. Properly compensated, undercompensated and overcompensated 10:1 probe.