Skip to content
PCBITE-7010

SQG30-AC – 3.0 GHz low impedance 10:1 passive AC probe

Handsfree 3 GHz AC-coupled 10:1 passive probe with SMA output, for 5 to 6 Gbps data and RF on DC-biased lines.

Secure paymentGlobal deliveryPremium quality
In stockDelivery: 1-2 business days

249 € excl. VAT

Accessories

PCBITE-7014
In stockDelivery: 1-2 business days
PCBITE-7016
In stockDelivery: 1-2 business days
PCBITE-7017
In stockDelivery: 1-2 business days
PCBITE-7021
In stockDelivery: 1-2 business days

Introduction

A 3 GHz AC-coupled probe for 5 and 6 Gbps data lanes and RF on DC-biased lines. Place it on the test point and let go, with no soldering and no active probe electronics.

The SQG30-AC is a 10:1 passive low impedance probe with AC coupling and a bandwidth above 3 GHz. Its SMA output connects to oscilloscopes and other instruments with a 50 Ω input, and the probe reaches fast digital and RF test points directly on the PCB without soldered wires.

The AC coupling blocks up to 50 V DC, so no DC current flows between probe and circuit and the operating point of the device under test is left undisturbed. The response is flat within ±0.5 dB from 1 kHz to 2.6 GHz and the low-frequency cutoff is 359 Hz, so the small high-frequency content on a biased line can be viewed at full oscilloscope sensitivity.

With usable data rates up to 6 Gbps at the fundamental, the probe covers DC-biased serial lanes such as SuperSpeed USB at 5 Gbps, PCIe Gen 2, SATA III and DisplayPort up to HBR2, and reaches all the way to HDMI 2.0 TMDS lanes at 6 Gbps. ECL, PECL and LVPECL signaling is covered as well. On the RF side it reaches the 2.4 GHz band used by Wi-Fi and Bluetooth, GNSS receivers and other front-ends below 3 GHz, and supply noise, ripple and decoupling problems on power and control lines can be traced the same way. Besides oscilloscopes, the probe works with sampling oscilloscopes, network analyzers, spectrum and modulation analyzers, receivers, power meters and millivoltmeters with a 50 Ω input.

The nominal tip impedance is 500 Ω and the typical tip capacitance 0.35 pF. The return loss for the probed line is typically -26 dB to -3.7 dB from 0 to 3 GHz, and on a 50 Ω line the probe lowers the amplitude by about 0.42 dB without reshaping the waveform, so scaling the result restores the level. The transition time is below 103 ps, ringing stays within 0.14 dB at 3 GHz and the additive noise is 156 µV.

Both ground options are included. The dual spring-loaded ground needles sit 2.3 mm (0.09 in) on each side of the signal needle, 4.6 mm (0.18 in) apart, and keep the full 3 GHz bandwidth. The ground spring reaches ground points 6.5 mm (0.26 in) away with the bandwidth limited to 2 GHz, so the dual needles are the choice above that. A spare spring-loaded test needle is included, and the needle is replaceable when it wears.

Each SQG30-AC has its own serial number (SPID), and the S-parameters measured on that probe can be downloaded for simulation or de-embedding. The insulated head is 90 mm (3.5 in) long and 8.9 mm (0.35 in) wide, the probe weighs 34 g (1.2 oz) with its 1.2 m (47 in) cable, and its low center of gravity keeps it in place in a PCBite holder through long captures or in the hand for quick checks. A storage case holds the probe together with the probe holder, an SMA wrench, color coded cable holders and a tip protection cap.

The probe is rated CAT 0 under IEC 61010-031:2022 for circuits not directly connected to mains, with a maximum continuous input of 6.0 V AC RMS at the probe tip.

Compatible accessories

  • 1X SQG30-AC 3.0 GHz low impedance 10:1 passive AC probe
  • 1X SQ probe holder for handsfree measurement
  • 1X Storage case for probe and accessories
  • 1X Ground spring 3.5 mm (SQG)
  • 1X Extra test needle (SQG)
  • 1X SMA wrench
  • 1X Set of cable holders (red, yellow, green, blue)
  • 1X Probe tip protection cap
  • 1X Dual ground spring needle, 3.5 mm
User guide SQG High-frequency probes Datasheet SQG-series high-frequency probes
Dimensions of SQG30-AC - 3.0 GHz low impedance 10:1 passive AC probe: SQG30 Probe
Brand

PCBite

Manufacturer

Sensepeek AB

Article number

PCBITE-7010

GTIN

7350145660489

Country of origin

Sweden

HS code

90309000

HTS code

9030906800

ECCN

EAR99

Safety information

See downloads

Package weight 750 g
Package dimensions 290 × 240 × 60 mm
MATERIAL

Made to last

Every material and design detail is chosen to last for years in a demanding lab environment.

Flexible arm
Flexible, adaptable, mechanically stable metal design
Test needle
Exchangeable, fine-pitch spring-loaded
Magnet
Strong N52 neodymium
Connector
SMA
MATERIAL
Flexible arm
Flexible, adaptable, mechanically stable metal design
Test needle
Exchangeable, fine-pitch spring-loaded
Magnet
Strong N52 neodymium
Connector
SMA

Made to last

Every material and design detail is chosen to last for years in a demanding lab environment.

APPLICATIONS

Built for the signals you work with.

SQG probe placed handsfree near the antenna feed of a small PCB, its cable connected to the RF input of a spectrum analyzer.
SQG probe with its spring-loaded dual ground placed handsfree on a high-speed trace of a PCB held by PCBite holders.
Handsfree probes with spring-loaded grounds on a high-speed PCB, wired to the oscilloscope inputs behind for clock and timing work.
PCB with multiple MMCX connectors and adapters for quick probe repositioning between test points
Two SQG probes on an RF test board, connected to port 1 and port 2 of a vector network analyzer to measure the circuit in place.

Probe RF traces, matching networks and PCB-mounted RF connectors without soldering a coax pigtail. Connect to a spectrum analyzer, receiver or power meter, and measure the signal where it actually runs.

Two SQG probes resting handsfree on the through line of a calibration board, wired to the analyzer ports for repeatable results.
REPEATABLE

Same setup. Same result.

RF measurements are only useful if you can repeat them. A handheld probe moves between readings, and a soldered connection changes the circuit you are measuring. SQG probes are handsfree and stay on the test point once placed, with no soldering and no complex fixtures, so the next measurement matches the last. Just position the probe and measure.

Oscilloscope probe connected to an instrument input through a PCBITE-7003 and a Huber+Suhner feedthrough termination as part of a frequency response measurement.
FREQUENCY RESPONSE

Flat where it matters.

Flat response helps maintain amplitude accuracy as frequency increases. The SQG30-AC stays within ±0.5 dB from 1 kHz to 2.6 GHz.

 

SQG probe on a PCB in PCBite holders, connected to an analyzer input, with the model and probe ID printed on its cable.
PROBE CLOUD

Probe-specific data, by serial number.

Every SQG probe is measured as part of production verification, with probe-specific S-parameter data stored in Probe Cloud. Enter the probe ID from the cable to access the measured response of that specific probe for further analysis or correction.

PATENTED GROUND DESIGN

Dual spring-loaded grounding.

High-end probes use a spring-loaded signal needle. The same principle is applied to ground through patented dual spring-loaded ground needles, improving contact stability and keeping the ground path short. On the SQG30-AC, the dual ground keeps the full 3 GHz bandwidth and the ground spring reaches 2 GHz.

 

Dual ground 3.5 mm needle geometry: 2.3 mm (0.09 in) from signal to ground needle and 4.6 mm (0.18 in) between the ground needles.
NEEDLE PITCH

Fixed spacing. Repeatable contact.

Know exactly where the needles land. The dual ground uses fixed geometry, so the signal and ground needles always land at known distances. The SQG30-AC uses 2.3 mm (0.09 in) from signal to ground and 4.6 mm (0.18 in) between the ground needles. The drawings show the exact needle geometry for each ground option, whether you use existing pads, exposed copper or dedicated test points.

 

Handsfree probes on one PCB, wired to a mixed signal oscilloscope, a vector network analyzer and a signal generator.
versatile

Not just for oscilloscopes.

SQG probes work with measurement instruments featuring a 50 Ω input, including oscilloscopes, sampling oscilloscopes, network analyzers, spectrum analyzers, receivers and power meters.

The inside of the protective EVA case showing the SQG60 6.0 GHz probe and accessories (PCBITE-7013)
PROTECTIVE CASE

A case that fits the probe.

Every SQG probe comes in a fitted EVA case, made to protect it for as long as you use it. Pack the probe and its accessories after a measurement, and everything is in place for the next one, whether it stays in the lab or travels with you.